Carrier 48fc 15 ton.

Carrier rooftops have high and low pressure switches, a filter drier, and 2-in (51mm) filters standard. FEATURES . Single cooling stage models are available from 3 - 10 ton. Two cooling stage models are available from 7.5 - 15 ton. SEER up to 13.0 (up to 13.4 with ECM motor) EER’s up to 11.1 (up to 11.4 with ECM motor)

Carrier 48fc 15 ton. Things To Know About Carrier 48fc 15 ton.

Performance Features. New unit control board with intuitive quick fan speed adjustment. New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single …Carrier’s WeatherMaker® 15 to 27.5 ton rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw collars, handled access panels, and more, we’ve made your unit reliable and easy to install, maintain, and use. Easy to install These WeatherMaker units are designed for dedicated factory-sup-A Pg 1 11-22 Replaces: 48FC-8-14-01SB. 48FC 08-16 size units are single-packaged electric cooling, gas heating units that are pre-wired and pre-charged with Puron® (R-410A) HFC refrigerant. The units are factory tested in both heating and cooling modes. These units meet the upcoming DOE-2023 (Department of Energy) and ASHRAE (American Society ...Performance Features. New unit control board with intuitive quick fan speed adjustment. New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single-stage cooling capacity 04-06 models, two-stage on 07-28 models. SEERs to 14.3, IEER of 15.0. HSPF to 8.2 and COP’s to 3.6.IEERs up to 15.2. All models are capable of either vertical or horizontal airflow. The Carrier rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw …

Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series — WeatherMaker® FC = 14.0 SEER Standard Efficiency, sizes 04-06 13.4 SEER2 Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 = Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas Heat 10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU ... 48fc-8-14-01si ; 48fcem 10t 208-230-3 ... Specifications. Brand ...

Performance Features. New unit control board with intuitive quick fan speed adjustment. New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single …PALM BEACH GARDENS, Fla., March 6, 2023 /PRNewswire/ -- Carrier Global Corporation (NYSE: CARR), the leading global provider of healthy, safe, sus... PALM BEACH GARDENS, Fla., Marc...

Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series — WeatherMaker® FC = 14.0 SEER Standard Efficiency, sizes 04-06 13.4 SEER2 Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 = Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas Heat View and Download Carrier 48FC M20 Series service and maintenance instructions online. Single Package Rooftop Gas Heat/Electric Cooling Unit with Puron (R-410A) Refrigerant 17.5-27.5 Nominal Tons. 48FC M20 Series air handlers pdf manual download. Also for: 48fc n20 series, 48fc m24...3 TON Medium Gas Heat 14 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU. ... 48FCEA04A2A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat A = One Stage Cooling Models ... Brand Carrier; Equipment Type Commercial Packaged Outdoor Unit; Fan Type Vane Axial; Gas Stages 1-Stage;6 TON High Gas Heat 14 SEER Standard EFFICIENCY Medium STATIC 460-3 VOLT GAS ELECTRIC RTU ... 48FCFM07A2A6-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ... New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single-stage cooling capacity 04-06 models, two-stage on 07-30 models. SEERs up to 14.0, IEER of 15.2. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit.

King saver weekly ad

RT-PRC094B-EN. Table 1. General data—heating performance – 7.5–12.5 tons. (a)Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards (ANSI). Ratings shown are for elevations up to 2,000 feet.

48FC units are single-packaged electric cooling, gas heating unit that are pre-wired and pre-charged with Puron® (R-410A) HFC refrigerant. The units are factory tested in both heating and cooling modes. Sizes 04-06 models use single-stage cooling capacity control. Size 07 models use two-stage cooling capacity control. FEATURES.48KC Sizes 04 to 06 Single Packaged Rooftop Units with Gas Heat. Product Data WeatherMaker®. Gas Heat/Electric Cooling Packaged Rooftop Units. 3 to 5 Nominal Tons. 2. The Carrier rooftop unit (RTU) was designed by customers for customers. With “no-strip screw” collars, handled access panels, and more we’ve made your unit easy to install ...Restore set-points for thermostat and humidistat (Y/N) _____. 2021 Carrier. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53480329-01 Printed in U.S.A. Form 48FC-8-14-01SI Pg CL-2 8-21 Replaces: New.6 TON High Gas Heat 14 SEER Standard EFFICIENCY Medium STATIC 460-3 VOLT GAS ELECTRIC RTU ... 48FCFM07A2A6-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ... Carrier rooftops have high and low pressure switches, a filter drier, and 2-in (51mm) filters standard. FEATURES . Single cooling stage models are available from 3 - 10 ton. Two cooling stage models are available from 7.5 - 15 ton. SEER up to 13.0 (up to 13.4 with ECM motor) EER’s up to 11.1 (up to 11.4 with ECM motor)

48FC WeatherMaker® Single-Packaged Rooftop Units with EcoBlue™ Technology - Low Heat. Carrier 3 Ton, 13.4 SEER2 Package RTU Low Gas Heating/Electric Cooling, Direct Drive/EcoBlue ,208/1. MFR: Item: 48FCDA04A2A30A0A0. Carrier 3 Ton, 13.4 SEER2 Package RTU Low Gas Heating/Electric Cooling, Direct Drive/EcoBlue ,208/3. MFR:According to the U.S. Energy Information Administration, as of March 2014, the cost of coal per short ton ranged from $12 to $65. The quality of the coal determines the pricing of ...7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU. SKU 48TCEM08A2A5-0A0A0. ... Brand Carrier; BTU Input 224000; Equipment Type Commercial Packaged Outdoor Unit; Fan Type Centrifugal; Frame Size 56; Gas Stages 2-Stage; Heat Size Medium Gas Heat; LEER 12.7;Field Convertible airflow (3−12.5 ton). Being able to convert a unit from vertical airflow to horizontal makes it easy to overcome job site complications. 12.5 ton models require a simple supply air duct cover to field convert from factory vertical to horizontal. Provisions for thru−the−bottom power entry capability as standardCarrier

Full-scale Carrier quality for a variety of equipment types. DXF/CAD templates are full scale 2D drawings of Carrier products. Drawings are provided for you to assist in the creation, modification, analysis, and optimization of a building design. ... 3-28 Ton Rooftop Units – 48/50TC(Q), 48/50KC(Q), 48/50HC(Q), 48/50LC, EnergyX® models. 48 ...

Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series — WeatherMaker® FC = 14.0 SEER Standard Efficiency, sizes 04-06 13.4 SEER2 Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 = Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas HeatView and Download Carrier 48HC*04–14 service and maintenance instructions online. Nominal 3 to 12.5 Tons With Puron (R410A) Refrigerant. 48HC*04–14 air conditioner pdf manual download. ... Air Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge ...Catalog No. 04-53480288-01 Printed in U.S.A. View and Download Carrier WeatherMaker 48TC Series service and maintenance instructions online. Single Package Rooftop Unit with Gas Heat/Electric Cooling and Puron (R-410A) Refrigerant. WeatherMaker 48TC Series air conditioner pdf manual download. 12.5 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU ... 48FCFM14A3A6-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ... is proprietary to carrier corporation and shall not be used or disclosed to others, in whole or in part, ... - 48fc packaged rooftop gas heating/electric cooling units - 14 seer 3, 4, 5 tons, 15 ieer 6 ton . project: ~untitled1 09/19/2020 prepared by: 12:13pm ...Time to clean out your attic or garage? Forget about settling for garage sale prices. These days, online auction sites and marketplaces make it easier than ever before to sell your...Air Conditioner Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting. ... Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) ... Page 32 Table 15 — Quick Test, Unit Configuration and Switch Check QUICK NORMAL TEST DISPLAY STEP NO. 0 or 1 0 …Carrier Manuals. Air Conditioner. 48TC series. Product data. Carrier WeatherMaker 48TC Series Product Data. Carrier gas heat/electric cooling packaged rooftop 3 to 15 nominal tons. Also See for WeatherMaker 48TC Series: Service and maintenance instructions (112 pages) , Installation instructions manual (64 pages) , A Pg 1 11-22 Replaces: 48FC-8-14-01SB. 48FC 08-16 size units are single-packaged electric cooling, gas heating units that are pre-wired and pre-charged with Puron® (R-410A) HFC refrigerant. The units are factory tested in both heating and cooling modes. These units meet the upcoming DOE-2023 (Department of Energy) and ASHRAE (American Society ...

Marc sallinger 9news

IEERs up to 15.2. All models are capable of either vertical or horizontal airflow. The Carrier rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw collars, handled access panels, and more, the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton Carrier WeatherMaker rooftop unit

With Weather Series Rooftop Units featuring EcoBlue™ Technology, Carrier is proving that not all rooftops are created equal. EcoBlue™ Technology includes a more compact vane axial fan, which is an industry first for packaged rooftop units, along with a simplified design that helps lower installation and maintenance costs. Turn to the experts today to learn …Replacement for. 48KCEA06A2A5-0A0A0 - 5.0T G/E RTU PURON 208/230-3 MED FAN; 48TJE006---5--GA - 5.0T G/E RTU 3PH STD HEAT W/ALT MTR; 48FCEA06A2A5-0A0A0 - 5 TON Medium Gas Heat 14 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU6 2 15.0 74 x 47 x 41 67 110 150 607 Gas Heating / Electric Cooling Models – 48FC Electric Heat / Electric Cooling & Cooling Only Models – 50FC Nominal Cooling Ton Size Cooling Stages AHRI Efficiency (SEER) IEER Dimensions (in) L x W x H Electrical Heat Nominal kW Range Approx. Unit Weight (lbs) 3 1 (14.0) 74 x 47 x 33 4.0 to 15.0 437Carrier 48fc 15 Ton, Carrier Commercial Packaged Outdoor Commercial Products Portland, OR, Commercial Cooling Showcase 2019 2019-05-06 ACHR NewsCarrier has introduced Weather Series Rooftop Units with EcoBlueTM Technology. One of EcoBlue's many innovative features is the exclusive beltless direct-drive vane axial fan that replaces traditional belt drive fans with a simpler, more compact design for improved performance and efficiency while decreasing maintenance and installation costs.We have 2 Carrier 48FC Series manuals available for free PDF download: Controls, Start-Up, Operation And Troubleshooting, Installation Instructions. Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting …8.5 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM09A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 09 = 8.5 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability …Carrier 3 Ton, 16.0 SEER Package RTU Low Nox Gas Heating/Electric Cooling, Two Stage Cooling, Direct Drive/EcoBlue ,208/1. MFR: Item: 48GCLM04A2A30A0A0. ... 15 years parts only heat exchanger - stainless steel; 5 years parts only compressor; 3 …7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU. SKU 48TCEM08A2A5-0A0A0. ... Brand Carrier; BTU Input 224000; Equipment Type Commercial Packaged Outdoor Unit; Fan Type Centrifugal; Frame Size 56; Gas Stages 2-Stage; Heat Size Medium Gas Heat; LEER 12.7;els are in addition to the 3 to 5 ton models with SEERs up to 17.5 and 12.5 to 23 ton models with IEERs up to 19.1 to provide a full range offering. Ultra high efficiency With IEERs up to 20.8, these new WeatherExpert models help to contrib-ute in LEED credits and help qualify for rebates. The high IEER efficiencies are

48TCFD24A2A5-6F0G0 - 20 TON High Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU; Documents. 48-50fc-20-30-01pd; 48fc-20-30-01si_rev_b; Specifications. Brand Carrier; Availability Available for Delivery; Warehouse Availability MALD; Equipment Type Commercial Packaged Outdoor Unit; Gas Stages 2 …Carrier air conditioners, for example, offer a variety of energy efficiency or SEER2* ratings, various types of comfort-enhancing technologies and even sound ratings. Installed costs might range from anywhere between $3,000 to $15,000 or more.Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series - WeatherMaker® FC – 14.0 SEER Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 – Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas Heat E = Medium Gas Heat F = High Gas HeatGAS HEATING/ELECTRIC COOLING ROOFTOP UNIT WITH PURON® REFRIGERANT COMMERCIAL ROOFTOP EQUIPMENT. GENERAL LIMITED WARRANTY STATEMENT – Carrier Corporation warrants this product against failure due to defects in material and workmanship under normal use and service, subject to the conditions, exclusions and time periods set forth herein.Instagram:https://instagram. did you hear about pizzazz answer key Description. 48FCFM16A3A6-0A0A0. 48FC = Gas Heat Packaged Rooftop. F = High Heat. M = Single Circuit, Two Stage Cooling Model. 16 = 15 Tons. A = No Smoke or CO 2 …7.5 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM08A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 08 = 7.5 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability … gem global electric motorcars Hey Everyone, Working on a Carrier RTU unit model# 48TCEA06A2A5A0A0A0. Customer complaint "thermostat has no power." Found 5 amp breaker tripped on transformer. Whenever R and Y1 closes it pulls 10 amps and trips 5 amp breaker. I removed wires from both contactor solenoids (24v circuit) and still trips. I …Carrier 48TC Gas/Electric 15 Ton Standard Efficiency Packaged Outdoor Unit 208/230-3-60 MED Static, Medium Heat ... Same footprint as installed Carrier 3-12.5 ton rooftops back to 1989, reducing installation costs and time ... PI-48FC-GC-01; Checklist - PI48TC-HC-01; Configuration - 33CS-68SI; inquirer crossword puzzle Replacement for. 48TCED08A2A6-0A0G0 - Gas Heat/Electric Cool Rooftop, 2-Stg 7.5T 460-3-60 Medium Fan; 48TCEM08A2A6-0A0A0 - 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 460-3 VOLT GAS ELECTRIC RTU boldt funeral home faribault minnesota obituaries PALM BEACH GARDENS, Fla., March 6, 2023 /PRNewswire/ -- Carrier Global Corporation (NYSE: CARR), the leading global provider of healthy, safe, sus... PALM BEACH GARDENS, Fla., Marc... evansville bmv hours Carrier huntington park power outage 6 TON High Gas Heat 14 SEER Standard EFFICIENCY Medium STATIC 460-3 VOLT GAS ELECTRIC RTU ... 48FCFM07A2A6-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ...Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series - WeatherMaker® FC – 14.0 SEER Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 – Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat 2019 ab frq Exceeded Department of Energy Advanced RTU Challenge by 15%; Exceeds ASHRAE 90.1 and Energy Star efficiency levels, as well as Consortium for Energy Efficiency (CEE) criteria; 3 to 5 ton models have two-stage cooling capacity control and 6 to 23 ton models have three-stage cooling capacity control; Up to 17.5 SEER and 20.8 IEERCarrier 48fc 15 Ton, Carrier Commercial Packaged Outdoor Commercial Products Portland, OR, Commercial Cooling Showcase 2019 2019-05-06 ACHR News ice cube world arena colorado springs There are 2,000 pounds in one ton. Tons and pounds are both units of measurement that describe mass. The abbreviation for ton is “T,” while the abbreviation for pound is “lb” or “l... doordash error geo service Carrier 48TC Gas/Electric 15 Ton Standard Efficiency Packaged Outdoor Unit 208/230-3-60 MED Static, Medium Heat ... Same footprint as installed Carrier 3-12.5 ton rooftops back to 1989, reducing installation costs and time ... PI-48FC-GC-01; Checklist - PI48TC-HC-01; Configuration - 33CS-68SI; diymoon carrier 48fc ton › ... Carrier 48FCFM07A3A6-0A0A0 TON High Gas Heat 14 SEER Standard EFFICIENCY High STATIC 460 VOLT GAS ELECTRIC RTU DCNE. 4.8 (195) · USD 30.8 · In stock. Description. The MRCOOL DIYM218HPC00C07 is a dual zone ceiling cassette mini split that offers 18,000 BTUs of cooling Free Shop now at.10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM12A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 12 = 10 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability Available for … holiday camplands andover 24 2 800 / 600 23000 12.0 15.0 30 2-1/2 1000 / 750 29000 12.0 15.0 36 3 1200 / 900 35400 12.5 16.0 42 3-1/2 1400 / 1050 42000 12.5 16.0 48 4 1600 / 1200 47500 12.3 16.0 60 5 1750 / 1200 57000 12.3 16.0 LEGEND dB ---Sound Levels (decibels) db—Dry Bulb SEER—Seasonal Energy Efficiency Ratio wb—Wet Bulb COP---Coefficient of PerformanceCarrier has introduced Weather Series Rooftop Units with EcoBlueTM Technology. One of EcoBlue's many innovative features is the exclusive beltless direct-drive vane axial fan that replaces traditional belt drive fans with a simpler, more compact design for improved performance and efficiency while decreasing maintenance and installation costs. els are in addition to the 3 to 5 ton models with SEERs up to 17.5 and 12.5 to 23 ton models with IEERs up to 19.1 to provide a full range offering. Ultra high efficiency With IEERs up to 20.8, these new WeatherExpert models help to contrib-ute in LEED credits and help qualify for rebates. The high IEER efficiencies are